Design Features
Self Locking
Threaded closure locks automatically when nut detent mechanism engages the detents along the face of the body. Assembly and disassembly are performed by hand without tools.
Meets Military Requirements
Coupling design has been qualified to all applicable military specification requirements for flexible fuel coupling systems with service pressures of 125 PSIG (operating), 250 PSIG (proof), and 375 PSIG (burst), plus surge pressures to 270 PSIG and temperatures from -65°F to 450°F (except -72AB & -80AB, see factory for pressure data).
Self Bonding
Electrical bonding to class "S" of MIL-B-5087B is automatically provided when the coupling is assembled.
Flexible
Axial adjustment is shown in table. Angular misalignment is ±4° for full coupling.
Coupling Flanges
The coupling flanges are mechanically attached (swaged or welded) to tube ends. Information about tooling and installation procedure is available from Hydraflow upon request.
Non-captive
The 17J02 coupling is non-captive; it can be installed over flanges or pump ends with machined-on flanges.